Can Biohome Really Reduce Nitrate?
In this article, I’m going to share the results of my Biohome nitrate experiment.
Biohome, along with several other premium types of aquarium filter media, is often marketed as being able to reduce nitrate levels in aquariums1.
The idea is that the structure of the media creates areas with very little oxygen—known as anoxic and anaerobic zones—where specialized microorganisms can develop. These microorganisms can convert nitrate into nitrogen gas23, which then leaves the aquarium naturally.
To test whether this claim actually holds up, I set up four different experiments that ran for five months. Each test looked at how Biohome performed under slightly different conditions, with the main goal being to see whether it could reduce nitrate levels on its own.
If you’re short on time, here’s the quick takeaway: I started this experiment fairly skeptical of filter media that claim to reduce nitrate levels. However, based on the results of my testing, Biohome does appear capable of creating anoxic and anaerobic environments inside the aquarium.
The Experiment Setup

To keep the results as accurate as possible, I wanted to limit outside factors that could influence nitrate levels.
All of my aquariums are heavily planted, and aquarium plants naturally absorb nitrate from the water4. Because of that, using my existing tanks would make it difficult to tell whether any nitrate reduction was coming from the Biohome or the plants.
Instead, I used brand-new plastic storage bins for the experiment so that the only major variables would be the filter media and the conditions I created.
A Quick Note About Sponsorship
Before going any further, it’s worth mentioning that this experiment is not sponsored in anyway.
A couple of years ago I bought a large amount of Biohome Biogravel with my own money to use in some of my aquariums.
For this test, I reused that media—which hadn’t been used in years—along with a few brand-new aquarium filters.
The Control Test

The first setup was my control test, which contained only water and an ammonia solution.
The purpose of this container was to see what would happen without any Biohome at all. This provides a baseline so we can compare the other setups and see whether the media actually makes a difference.
I also added tap water conditioner to each setup. This removes chlorine and chloramines from tap water, which ensures that beneficial microorganisms can develop without being harmed.
Temperature Conditions
All four tests were run at room temperature over a period that crossed the British winter.
During this time, the room temperature dropped to around 18°C (64°F).
Initially, I was slightly concerned that these cooler temperatures might slow down the development of microorganisms, but based on the results, it doesn’t appear to have had a major impact.
Biohome Used As A Substrate

The second setup tested Biohome used as a substrate rather than filter media.
Instead of placing the media inside a filter, it was placed directly on the bottom of the container. The goal here was to limit the amount of highly oxygenated water flowing directly over the media, which could help create the low-oxygen zones needed for nitrate reduction.
For this test, I added 110 grams of Biohome, which is about a quarter of a pound. This matches the standard recommendation for the water volume used in this experiment1.
A research paper I found tested something similar using pumice and showed that it could develop microorganisms capable of reducing nitrate when used this way5. Because of that, I went into this test fairly confident that it might perform well.
Standard Stocking Test

The third setup followed the standard stocking recommendation for Biohome1.
Again, I used 110 grams of media, but this time it was placed inside a hang-on-back filter, which is how most aquarists would typically use it.
The first filter I used was quite small, and I quickly ran into a small issue. The Biogravel kept spilling into the intake chamber, so I added a small piece of filter floss to help hold the media in place.
Another potential complication with this setup is that the smaller filter has a shorter spillway when placed on these storage boxes, which may introduce slightly more air into the water.
Heavy Stocking Test

The final setup tested the heavy stocking or predator fish recommendation1.
For this experiment, I used 220 grams of Biohome, which is roughly half a pound. This higher amount of media is recommended for aquariums with a larger bioload, either because the tank contains more fish or because the fish produce more waste from protein-heavy diets.
To hold the larger amount of media, I used an AllPondSolutions hang-on-back filter, which has a larger filter chamber.
Just like the previous setup, I added a small piece of filter floss to stop the Biohome from moving into the intake chamber and potentially interfering with the impeller.
One difference worth noting is that the spillway on this filter actually touches the water surface, which means it introduces less air into the system compared to the smaller filter used earlier.
Simulating Fish Waste With Ammonia

Once everything was set up, I needed a way to simulate the waste that fish would normally produce.
Instead of adding fish, I dosed each container with Dr. Tim’s Ammonia Solution. While fish food could have been used and allowed to decay, using pure ammonia is far more precise and easier to control.
Each setup was dosed to 2 ppm of ammonia, which is the standard recommendation from Dr. Tim’s when cycling a new aquarium6.
However, the heavy stocking test—with 220 grams of Biohome—was dosed to 4 ppm of ammonia to simulate the higher bioload that this amount of media is designed to handle.
After dosing, I tested each container to confirm the ammonia levels were correct. This ensured that the 2 ppm and 4 ppm setups started at the intended concentrations.
A Small Issue During Setup
Before moving on to the results, there was one small issue worth mentioning.
During the first few days, the Biogravel in the smaller Nicrew filter kept slipping into the intake chamber and touching the impeller, which caused the filter’s safety shut-off to trigger.
To avoid this interfering with the experiment, I replaced that filter with another AllPondSolutions hang-on-back filter, which solved the issue.
The Control Test

Starting with the control test, very little actually happened over the five-month period—which is pretty much what I expected.
This setup had very limited surface area for microorganisms to grow on compared to the amount of ammonia that was added to the water.
In addition, there was no water flow and no heater, which likely slowed the development of beneficial microorganisms even further.
Because of these conditions, the nitrogen cycle developed very slowly in this container.
Nitrogen Levels After Five Months
By the five-month mark, my test kit showed small amounts of nitrite and nitrate beginning to appear.
However, the vast majority of the nitrogen in the system was still present as ammonia or ammonium, which indicates that the nitrogen cycle had only progressed slightly during the 5 month test.
Why This Test Still Matters
Even though not much happened in this setup, the control test is still very important for the experiment.
It shows what happens when no Biohome media and no water flow are present, giving us a baseline to compare against.
With this reference point, it becomes much easier to see whether the other setups performed differently because of the Biohome.
The Substrate Test

Next is the test where Biohome was used as a substrate rather than being placed inside a filter. This is where the results started to become more interesting.
After the first month, very little had changed in the container.
However, this setup had no water flow and relied mostly on natural convection, which occurs when small temperature differences in the water cause gentle movement.
Because of this limited water movement, the process may have developed more slowly than it would in a typical filtered aquarium.
Results After Two Months

By the second month, a large portion of the ammonia had been depleted.
Interestingly, there were only very small amounts of nitrite and nitrate appearing in the tests. This suggests that Biohome’s claim of cultivating specialized microorganisms that can remove nitrogen from the system may actually have some validity.
Results After Three And Four Months

By month three, most of the ammonia had disappeared, leaving only small traces of nitrite and nitrate.
Then by month four, my test kit showed no detectable nitrogen compounds at all.
These results are very similar to what was observed in the pumice research study5 I mentioned earlier, where porous rock was able to support microorganisms that remove nitrogen from the water.
The main difference is that the process took slightly longer in my test, which I suspect may be due to the cooler winter temperatures during the experiment.
Standard Stocking Test

Next is the test based on the standard stocking recommendation, where 110 grams of Biohome was placed inside a hang-on-back filter.
Overall, I do think this test still suggests that Biohome can create anoxic and anaerobic zones. However, the experiment itself didn’t go as expected.
During the first month, everything appeared to be progressing normally.
My test kit was showing high levels of nitrite and nitrate, which suggested that the nitrogen cycle was developing as expected.
An Unexpected Change

However, by month two, something unusual happened.
The nitrite and nitrate levels dropped, while ammonia levels increased, even though no additional ammonia had been added to the container.
At first glance, this seems confusing.
In the aquarium hobby, we usually think of the nitrogen cycle as a one-way process:
- Fish waste produces ammonia
- Beneficial microorganisms convert ammonia into nitrite
- Other microorganisms convert nitrite into nitrate
From there, nitrate is typically removed through water changes, plant growth, or in some cases, through microorganisms that convert it into nitrogen gas, which escapes from the water.
Another Possible Nitrogen Pathway
However, there is another process that can occur in low-oxygen environments, which is more commonly discussed in agriculture. This process is known as dissimilatory nitrate reduction to ammonium, or DNRA.
Like denitrification, DNRA also occurs in areas where oxygen levels are very low. The key difference is what happens to the nitrate.
Instead of converting nitrate into nitrogen gas and removing it from the system, DNRA converts nitrate into ammonium7.
Because my liquid test kit measures total ammonia nitrogen8, rather than just free ammonia, it also detects ammonium. That may explain why the ammonia readings increased during this part of the experiment.
Why DNRA Can Be Useful in Agriculture
In agriculture, this process can actually be helpful.
For example, in environments like rice paddies, DNRA keeps nitrogen within the soil where crops can continue to use it, rather than allowing it to escape into the atmosphere.
However, in a non-planted aquarium, this process could potentially cause issues.
Why This Could Be A Problem In Aquariums
Some types of bacteria that develop in aquariums are capable of converting ammonium back into nitrite9.
If that happens, the nitrogen in the tank could start cycling in a loop:
- Nitrate becomes ammonium
- Ammonium becomes nitrite
- Nitrite becomes nitrate again
If nitrogen keeps cycling like this instead of being removed, nitrate and ammonia could build up over time.
In that situation, you would still need water changes or live plants to keep nitrogen levels under control.
But if you are relying on water changes or plants anyway, that removes much of the potential benefit of using expensive, premium filter media like Biohome in the first place.
A Possible Benefit For Planted Tanks

There is one niche argument that could be made in favor of this process in planted aquariums.
DNRA converts nitrate into ammonium, which is the form of nitrogen that plants ultimately use. Normally, plants absorb nitrate and then internally convert it into ammonium through a process called nitrate reduction10.
Plants then use that ammonium to produce important biological compounds such as:
- Amino Acids
- Proteins
- Chlorophyll
- DNA
However, this would be a very niche advantage, and most aquarists—including myself—are perfectly happy letting plants simply absorb nitrate and perform this conversion themselves.
A Possible Explanation
I only recently became aware of DNRA while trying to understand what might have happened in this test, so I haven’t done a huge amount of research into it yet.
However, it does appear that water temperature can influence which types of microorganisms become dominant11.
Because of that, my current theory is that the cooler winter temperatures in my fish room, which dropped to around 18°C (64°F), may have encouraged microorganisms responsible for DNRA to develop during this test.
The Heavily Stocked Test

Next is the heavily stocked test, which used 220 grams of Biohome to simulate the higher bioload you might see in a tank with more fish or fish that produce more waste.
Like the standard stocking experiment, this setup also had a few unexpected moments along the way.
By the end of month one, the results were looking promising. Ammonia levels had dropped significantly, while only small amounts of nitrite and nitrate appeared on the test kit.
Another Unexpected Shift

However, by month two, the results started to change.
Ammonia levels had increased again, even though no additional ammonia had been added to the system.
At the same time, there was no detectable nitrite or nitrate.
This was similar to what happened in the standard stocking test, and again suggests that DNRA may have temporarily taken over. In this process, nitrate is converted back into ammonium rather than being removed from the system.
The System Stabilizes

By month three, the situation shifted again.
Ammonia levels had lowered, there was still no detectable nitrite, and this time we began to see small amounts of nitrate appearing.
By month four, both ammonia and nitrite were undetectable, with only a small amount of nitrate remaining.
Then by month five, no nitrogen compounds were detectable in the water at all.
What This Suggests

These results suggest that Biohome can develop anoxic and anaerobic environments capable of removing nitrogen from the system, which supports the claims made about this type of filter media.
However, one thing I’m still not entirely sure about is why DNRA appeared to take hold earlier in this test, only for denitrifying microorganisms to eventually become dominant.
This is quite different from the standard stocking test, where DNRA seemed to remain dominant and continued holding nitrogen in the system as ammonium.
A Possible Explanation
My current theory is that temperature differences may have played a role.
This particular container was placed on the bottom shelf of my rack, and cooler water naturally tends to settle lower in a room due to convection.
As the seasons changed during the experiment, it’s possible that the water temperature in this container temporarily entered a range that favored DNRA, before later dropping into a range that was more favorable for denitrification, which actually removes nitrogen from the system.
Interestingly, at least one research paper has documented similar shifts, showing that different temperature ranges can favor different microbial pathways11.
This means systems can sometimes move back and forth between DNRA and denitrification depending on environmental conditions.
Final Thoughts
To quickly wrap things up, a few unexpected results did appear during the testing. However, the overall findings were still quite interesting.
Based on what I observed during these experiments, I am fairly confident that Biohome can support anoxic and anaerobic environments inside an aquarium.
These low-oxygen areas appear capable of supporting microorganisms that can eventually remove nitrogen from the system.
Why I Personally Won’t Be Using It
Even though the results suggest that Biohome does work as advertised, I personally don’t plan to use it in my own aquariums.
That’s mainly because I focus on low-tech planted tanks, where nitrate is usually seen as a valuable nutrient for plants rather than something that needs to be removed from the water.
In planted aquariums, nitrate acts as a source of nitrogen that plants use to grow, so reducing it too aggressively can actually work against the goals of many planted tank setups.
A Small Niche Use Case
As mentioned earlier, there is one niche scenario where DNRA could potentially be useful in a planted aquarium.
Because DNRA converts nitrate into ammonium, it could theoretically help balance situations where heavy plant growth is rapidly consuming nitrate from the water column.
However, this would be a very specific use case, and when you consider the price of Biohome—along with the fact that my results suggest the outcome may vary depending on which microorganisms develop—I personally don’t see much need for it in most aquariums.
One Thing I Didn’t Test
One thing I didn’t test during this experiment is whether these specialized microorganisms can survive routine filter maintenance.
When we clean aquarium filters, the media is usually removed from the water temporarily. Based on some of the research I’ve read, the microorganisms responsible for these processes require very specific oxygen conditions, so exposing the media to open air could potentially disrupt those colonies.
This is something that would be interesting to explore in a future experiment.
The Bottom Line
Overall, based on my testing, Biohome does appear to do what it claims.
It seems capable of developing the low-oxygen environments needed for microorganisms that can remove nitrogen from aquarium water, although the exact microbial processes that develop may vary depending on the conditions.
Source
- Biohome Media – https://filterpro.co.uk/biohome-media-3-c.asp ↩︎
- Isolation and Characterization of a Novel Denitrifying Bacterium with High Nitrate Removal: Pseudomonas stutzeri. Journal of Applied Microbiology, 101(5), 1151–1161. Retrieved from https://www.researchgate.net/publication/228496260_Isolation_and_characterization_of_a_novel_denitrifying_bacterium_with_high_nitrate_removal_Pseudomonas_stutzeri ↩︎
- Biological Nitrogen Removal from Wastewater by Paracoccus denitrificans ISTOD1: Optimization of Process Parameters Using Response Surface Methodology. Journal of Environmental Management, 231, 622–630. Retrieved from https://www.researchgate.net/publication/330134206_Biological_nitrogen_removal_from_wastewater_by_Paracoccus_denitrificans_ISTOD1_optimization_of_process_parameters_using_response_surface_methodology ↩︎
- Nitrate removal from synthetic medium and groundwater with aquatic macrophytes – https://www.sciencedirect.com/science/article/abs/pii/S0011916409002331 ↩︎
- Optimization and evaluation of a bottom substrate denitrification tank for nitrate removal from a recirculating aquaculture system – https://www.sciencedirect.com/science/article/abs/pii/S1001074212602484?via%3Dihub ↩︎
- What is Fishless Cycling? – https://www.drtimsaquatics.com/resources/fishless-cycling/ ↩︎
- Dissimilatory nitrate reduction to ammonium (DNRA): A unique biogeochemical cycle to improve nitrogen (N) use efficiency and reduce N-loss in rice paddy – https://www.sciencedirect.com/science/article/abs/pii/S2452219824000284 ↩︎
- AMMONIA (NH3/NH4+) TEST KIT INSTRUCTIONS – https://apifishcare.com/pdfs/products-us/ammonia-test-kit/api-ammonia-test-kit-instruction-manual.pdf ↩︎
- Heterotrophic nitrification – An eternal mystery in the nitrogen cycle – https://www.sciencedirect.com/science/article/pii/S0038071722000682 ↩︎
- Interactions between nitrate and ammonium in their uptake, allocation, assimilation, and signaling in plants – https://academic.oup.com/jxb/article/68/10/2501/2731728 ↩︎
- The competition between heterotrophic denitrification and DNRA pathways in hyporheic zone and its impact on the fate of nitrate – https://www.sciencedirect.com/science/article/abs/pii/S0022169423011174 ↩︎